EA800 Console Input Voltage 11 to 26VDC @ ≤ 500mA current draw
Wireless Sensor Input Voltage
(EA-WMFS, EA-WTS, EA-WHS)
12VDC @ ≤ 100mA current draw via 2.1 mm barrel plug,
center positive OR 2xAA Alkaline Batteries (1.5V Cell)
EA800 Console Auxiliary Output
Voltage
Equivalent to DC Input Voltage used: 11 to 26VDC.
(Maximum output current 0.5A).
Environmental Operating Range
(EA800, EA-WMFS, EA-WTS,
EA-WHS)
Temperature: 0°C to 50°C (32°F to 122°F). Not for
installation inside coolers or freezers.
Humidity: 5% to 95% RH, non-condensing.
Ambient Environmental Quality Indoor use intended, non-corrosive environment.
Relay Contact Ratings Max 30VDC @ 1 Amp, resistive
EA800 Real-Time Clock Battery CR2032 (3V Cell)
Ethernet (EA800-ip only) 10/100BASE-TX/FX; fully compliant to IEEE 802.3u standard
QUICK START GUIDE
This guide provides basic setup instructions for the
EnviroAlert EA800 and EA800-ip Critical Condition
Monitoring System and associated sensors. Installers
should refer to the Installation Manual (found online
at www.winland.com) for complete instructions and
specifications, and to become familiar with the many
features provided by the EA800. The EA800 allows
connection of up to 4 wired and 4 wireless sensors.
To use the EA800-ips advanced features, set up an
account at www.ea800ip.com. Since the EA800-ip
utilizes a cloud computing architecture, no client
software is required.
READ THE INSTALLATION/OWNERS MANUAL FOR COMPLETE INSTRUCTIONS.
Installation/Owner’s Manual can be found online at www.winland.com
All power terminals must be connected to a Class 2 power limited circuit complying with
National Electrical Code NFPA 70, Article 725. Where required, this equipment is to be
isolated from the main supply by a limited power source as specified in EN60950.
Batteries shall not cause explosion or produce a fire hazard as a result of excessive charge
or discharge.
Ensure all wiring for wired sensor connections is done before powering on or
programming the EA800 console.
If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
1950 Excel Drive • Mankato, MN 56001 USA
(Tech Support 8:00am - 5:00pm Central)
(800) 635-4269 • (507) 625-7231 P • (507) 387-2488 F
www.winland.com
INSTALLATION OVERVIEW
1. Installing Base Console
Do not connect or disconnect power, sensor, or alarm wiring
while power is applied. Connecting and disconnecting the
EA800 base console with power connected may damage the
base console or result in improper or unreliable operation.
Connection of unsuitable loads to this connection may
damage the power supply and EA800 base console, or result
in improper or unreliable operation.
Using a terminal block adapter, connect power supply + and - leads to POWER IN (+) and
(-) on J5. Observe proper polarity.
EA800 Input Voltage: 11 to 26VDC at ≤ 500mA
Note: The input voltage specification does not include requirements for loads connected to
Aux Power Out.
If Aux Power Out is to be used, connect + and - leads to AUX POWER OUT (+) and (-) on
J5 using a terminal block adapter. When base console is powered, a 30-minute timer starts.
The console will alarm after this timer expires unless one or more sensors are installed.
D-011-0153 Rev F (02/2012)
Page view 0
1 2

Summary of Contents

Page 1 - INSTALLATION OVERVIEW

PowerInAux PowerOutJ6J51 2 3 4J10J8 J9Relay Outputs2 3 4 5 6 7 8 AuxNO COM NCNO COM NC NO COM NC NO COM NC NO

Page 2 - Reset Button

2. Unlocking/Locking Base ConsolePress F1 to unlock base console. The default password is 0800.See Installation/Owner’s Manual to customize password.

Comments to this Manuals

No comments