SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
D I R E C T V E N T F I R E P L A C E
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNERS MANUAL
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
This appliance may be installed in an after-market
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certied kit
is used.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open ame.
• Do not try to light any appliance.
• Do not touch any electrical switch or use any phone
in your building.
• Immediately call your gas supplier from a neigh-
bours phone. Follow the gas supplier’s instruc-
tions.
• If you cannot reach your gas supplier, call the re
department.
WARNING
If the information in this manual is not followed
exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Installation and service must be performed by
a qualied installer, service agency or the gas
supplier.
FOR YOUR SAFETY
Do not store or use gasoline or
other ammable vapours and
liquids in the vicinity of this or any
other appliance.
50-1268
Massachusetts installations (Warning): This product must be installed by a licensed
plumber or gas tter when installed within the Commonwealth of Massachusetts.
Other Massachusetts code requirements: Flexible connector must not be longer than
36in., a shut off valve must be installed; only direct vent sealed combustion products
are approved for bedrooms/bathrooms. A carbon monoxide detector is required in all
rooms containing gas red direct vent appliances.
Haven
Page view 0
1 2 3 4 5 6 ... 40 41

Summary of Contents

Page 1 - OWNER’S MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.D I R E C T V E N T F I R E P L A C EB Y :

Page 2 - Safety Precautions

10Maintenance And ServiceCLEANING DECORATIVE SURFACES:Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has

Page 3 - Table of Contents

11Maintenance And ServiceFUEL CONVERSION:TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLYPlease read and understand these instructions before instal

Page 4 - Codes And Approvals

12Maintenance And Serviceb) Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 10), rotate it counter-

Page 5 - Specifications

Initial InstallationQUALIFIED INSTALLERS ONLYINTRODUCTION:This section of the owner’s manual is for the use of qualied technicians only. Firepla

Page 6 - Operating Instructions

Initial InstallationQUALIFIED INSTALLERS ONLYThe framing boards may touch the top, side and back standoffs, but no insulation or other material can be

Page 7

15Initial InstallationQUALIFIED INSTALLERS ONLYFigure 20. Top Mounting brackets.FRAMING MOUNT BRACKETS:DrywallWood FramingFront Tabs; bent up &sc

Page 8

Initial InstallationQUALIFIED INSTALLERS ONLYDrywallPlywoodBrickDrywallPlywoodTileDrywallPlywoodFigure 21. Bottom Mounting Holes.6BottomMountingHoles

Page 9

17Combustible HeaderCombustible Facing(up to 1" (25mm) thick)317/8"(810mm)7"(178mm)31/2"(89mm)10"(254mm)111/2"(292mm)101

Page 10 - Maintenance And Service

1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code.2 In accordance with the current ANSI Z223.1 NFPA 54, National Fu

Page 11

19KIT COMPONENTS:Qnty Description Qnty Description1 Horizontal direct vent termination cap 4 Wire spacers1 Flue collar adapter 1 4 oz tube Mill-Pac Se

Page 12

2FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All ENVIRO gas-red appliances must b

Page 13 - Initial Installation

Flue Pipe AdaptorWall FramingWall ThimbleFire StopExhaust 4" Flex PipeCombusion Air 6 5/8" Flex PipeWire Spacers9. Install the ex pipe as

Page 14

21WARNING: Do not mix parts from different vent manufacturers’s systems.EXCEPTION TO WARNING: This product has been evaluated by Intertek for usi

Page 15

Figure 32. Vent Framing Through Wall/Ceiling.Figure 31. Vent Pipe Clearances.2" (51mm)711/16" (195mm)39"(991mm)FramingJoists/Studs10”10

Page 16

230” (0m)0”(0m)10’ (4.72m)15’(7.09m)15’ (7.09m)20’ (9.45m)32’ (15.12m)17’(8.03)1VentRestrictionPositions39” (99cm)from the floor234525’ (11.81m)30’ (1

Page 17

Wall framingHorizontal wallterminationWall thimblefire stopRigid Coaxial PipeElbowInitial InstallationQUALIFIED INSTALLERS ONLYHORIZONTAL TERMINATION:

Page 18

25Initial InstallationQUALIFIED INSTALLERS ONLYStep 3. To install the Round Support Box/Wall Thimble in a at ceiling, cut a 10 inch (25.4 c

Page 19

Initial InstallationQUALIFIED INSTALLERS ONLYSTEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should

Page 20

27NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet

Page 21 - 8” pipe, adjustable

INSTALLATION OF ELECTRICAL WIRING FOR THE OPTIONAL FAN KIT:Figure 40. Wiring Diagram For Gas Valve.COOL/HEATPROGRAMDOWNUP70°F70°FONOFFOptionalRemoteC

Page 22

29Initial InstallationGAS LINE CONNECTION AND TESTING:WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to

Page 23

Table of Contents3Safety Precautions...

Page 24

Secondary InstallationQUALIFIED INSTALLERS ONLYOPTIONAL FAN KIT INSTALLATION:If the Haven is installed the burner and valve assemblies must be removed

Page 25

31Figure 48. Install Fan Control Box.Figure 49. Install Fan Control Nut.Secondary Installation6. Re-install the screws for the back cover and the stan

Page 26

Figure 52. Charcoal Pieces Installation.Figure 53. Ember Placement.Secondary Installation6. Install the two (2) grommets; place a 8-32 x ” bolt th

Page 27

33Secondary InstallationFigure 54. Left & Right Logs Installation.Figure 56. Haven complete log set-up with embers burning.Maintenance: Once a ye

Page 28

Secondary InstallationINSTALLATION OF STEEL FIREBOX LINER OR OPTIONAL CERAMIC FIREBOX LINER:NOTE: The ceramic liner is fragile and should be handled g

Page 29

35TroubleshootingProblem Possible Cause SolutionThe main burner does not ignite when called for.The gas valve may not be on. • Check that the gas

Page 30 - Secondary Installation

Parts List - ComponentsReference NumberPart Description Part Number1 120°F Ceramic Fan Temperature Sensor EC-0012 S.I.T. Nova Valve NG Convertible 50-

Page 31

37Parts List - OptionsReferance NumberPart Description Part Number20 Firebox Liner - Bankers Brown Brick 50-120920 Firebox Liner - Arizona Stucco 50-1

Page 32 - Figure 53. Ember Placement

Parts Diagram - ComponentsHaven Fireplace201119681034185917271615141311221The Haven - ComponentsDecember 200538

Page 33

39Parts Diagram - FasciaThe Haven - FasciaMay 200524222327282526

Page 34

4DIRECT VENT ONLY: This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.This ap

Page 35 - Troubleshooting

40WarrantySherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This Limited Lifetime Warranty covers the appliance for a

Page 36 - Parts List - Components

41Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Page 37 - Parts List - Options

1011/16"(272mm)45o63/16"(156mm)6"(152mm)101/16"(256mm)91/16"(230mm)97/16"(240mm)331/2"(852mm)331/4"(845mm)911/

Page 38 - Parts Diagram - Components

Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before OperatingWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTI

Page 39 - Parts Diagram - Fascia

2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several t

Page 40 - Warranty

8Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before OperatingA) Make sure the pilot is lit.B) Turn gas

Page 41 - Installation Data Sheet

Maintenance And ServiceROUTINE MAINTENANCE:At least once a year, run through the following procedures to ensure the system is clean and working proper