Enviro Westport C-10794 User Manual

Browse online or download User Manual for Kiln Enviro Westport C-10794. Enviro Westport C-10794 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 45
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNERS MANUAL
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
50-1033
Westport
This appliance may be installed in an after-market
permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certied kit is used.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
ame.
• Do not try to light any appliance.
• Do not touch any electrical switch or
use any phone in your building.
• Immediately call your gas supplier from
a neighbours phone. Follow the gas
suppliers instructions.
• If you cannot reach your gas supplier,
call the re department.
WARNING
If the information in this manual
is not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of
life. Installation and service must be
performed by a qualied installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
ammable vapours and liquids in the
vicinity of this or any other appliance.
Massachusetts installations (Warning): This product must be installed by a licensed
plumber or gas tter when installed within the Commonwealth of Massachusetts.
Other Massachusetts code requirements: Flexible connector must not be longer than
36in, shut-off valve must be a “T” handle gas cock; only direct vent sealed combustion
products are approved for bedrooms/bathrooms; replace dampers must be removed
or welded in the open position prior to the installation of a replace insert or gas log.
Page view 0
1 2 3 4 5 6 ... 44 45

Summary of Contents

Page 1 - Westport

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R I E S

Page 2 - Safety Precautions

Maintenance And ServiceTO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLYFUEL CONVERSION:Warning: This conversion kit shall be installed by a qualie

Page 3 - Table of Contents

Step 8. Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood and reinstall the hood

Page 4 - Codes And Approvals

121 In accordance with the current CSA B149, Natural Gas and Propane Installation Code.2 In accordance with the current ANSI Z223.1 NFPA 54, National

Page 5 - Specifications

13Initial InstallationQUALIFIED INSTALLERS ONLYVENT PARTS:This replace have been tested and certied for use with SIMPSON DURAVENT TYPE GS PIPE FOR G

Page 6 - CAUTION:

VentRestrictorPositions543210’(0 m)0’(0 m)5’(1.52 m)5’(1.52 m)10’(3.05 m)10’(3.05 m)15’(4.57 m)15’(4.57 m)20’(6.10 m)25’(7.62 m)30’(9.14 m)18’(5.49 m)

Page 7 - Operating Instructions

15Initial InstallationQUALIFIED INSTALLERS ONLYPLANNING YOUR INSTALLATION:When planning your installation, it will be necessary to select the proper l

Page 8

Initial InstallationQUALIFIED INSTALLERS ONLYHORIZONTAL INSTALLATION:STEP 1. Set the appliance in the desired location. Check to determine if wall stu

Page 9

17and attach to the exterior wall with the four screws provided. Before attaching the vent termination to the exterior wall, run a bead

Page 10 - Maintenance And Service

18NOTES: (1) The four (4) wood screws provided should be replaced with the appropriate fasteners for stucco, brick, concrete, or other types of sidi

Page 11

STEP 3. To install the Round Support Box/Wall Thimble in a at ceiling, cut a 10” square hole in the ceiling, centered in the hole drille

Page 12 - Initial Installation

2FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All ENVIRO gas-red appliances must b

Page 13 - 8” pipe, adjustable

down to the roof level, as shown in Figure 24. Tighten the clamp around the pipe section. Use a level to make sure the pipe is truly vertical. With ro

Page 14

21(2) Any occupied areas above the rst oor, including closets and storage spaces, which the vertical vent passes through, must be enclosed. T

Page 15

Figure 28: Cathedral Ceiling Support Box Leveling.Figure 29: Cathedral Ceiling Support Box Installation.STEP 6. Complete the cathedral ceiling install

Page 16

233. Set the appliance in the desired location. Temporarily place a 24” (61 cm) section with the non-crimped end on the unit 4. Install th

Page 17

Figure 32: Assembly of Venting Kit.20. Align all straight sections of pipe, slipping all joints together and installing with three (3) sheet metal scr

Page 18

25Initial InstallationQUALIFIED INSTALLERS ONLYVENTING INTO A CLASS ‘A’ CHIMNEY:This model is also certied and tested to vent into CLASS ‘A’ wood sto

Page 19

Firebox TopFlue CollarAdapterUndo four "screws thathold flue collarelbow to unit.Figure 34: Step 3 of Converting Top Vented into Rear Vented.Fig

Page 20

27Initial InstallationQUALIFIED INSTALLERS ONLYINSTALLATION OF TOP VENTED; HORIZONTAL TERMINATION:SidingExterior wallDrywallVent pipeInsidefinished co

Page 21

28Initial InstallationQUALIFIED INSTALLERS ONLYFREESTANDING DRAFTHOOD ADAPTOR:This Drafthood Adaptor is a complete assembly and is ready to t onto yo

Page 22

29Initial InstallationGENERAL VENTING INFORMATION:Canadian InstallationsThe venting system must be installed in accordance with the current CSA B149 i

Page 23

Table of Contents3Safety Precautions...2Table of Con

Page 24 - QUALIFIED INSTALLERS ONLY

30Initial Installation4. After a minimum of 10 minutes operation, test the chimney draft with a smoke match at the top row of the pattern to conrm th

Page 25

31Initial InstallationQUALIFIED INSTALLERS ONLYGAS LINE CONNECTION AND TESTING:WARNING: Only persons licensed to work with gas piping may make the nec

Page 26

32Figure 45: Gas Control Valve and Optional Thermostat Wiring.Initial InstallationQUALIFIED INSTALLERS ONLYELECTRICAL REQUIREMENTS FOR GAS VALVE AND O

Page 27

Fan assemblyValve coverControl panel(Fan control location)Screw holeFigure 47: Optional Blower (Fan) Installation.Secondary InstallationINSTALLATION O

Page 28

341. Carefully remove logs from box. Check to ensure there is no damage. It is very important to install all logs in their proper position

Page 29

Secondary InstallationCAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED.Important note: When the unit is turned on for the rst

Page 30

36Figure 57: Top brick panel in place, screws shown. Figure 58: Back brick panel in place.Figure 59: Side brick panels in place.Figure 56: Brick panel

Page 31

Trouble ShootingProblem Possible Cause SolutionSpark will not light the pilot after repeatedly pressing the spark ignitorDefective piezo ignitor. • Ch

Page 32

Reference Number Part Description Part Number1 Top Vent Insert Piece - Painted EGWP-5031 Top Vent Insert Piece - Antique White EGWP-503AW1 Top Vent In

Page 33 - Secondary Installation

39Reference Number Part Description Part Number6 Cast Leg (Each) - Painted EGWP-5086 Cast Leg (Each) - Antique White 50-3756 Cast Leg (Each) - Diamond

Page 34

4DIRECT VENT ONLY: This type is identied by the sux DV. This appliance draws all of its air for combustion from outside the dwelling, through a spec

Page 35

Parts Diagram - CastWESTPORT - CastingsJanuary 200540

Page 36

41Parts List - ComponentsReference NumberPart Description Part Number9 120° Ceramic Fan Temperature Sensor EC-00110 S.I.T. Nova Valve NG (50% Turn Do

Page 37 - Trouble Shooting

Parts List - ComponentsReference NumberPart Description Part Number17 Rating Plate (Label) 30-04918 Gas Valve Cover 30-050Flue Connection 30-05119 Inn

Page 38 - Parts List - Cast

43Parts Diagram - ComponentsWESTPORT - ComponentsJanuary 2005

Page 39

WarrantySherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This limited lifetime warranty covers the appliance for a per

Page 40 - Parts Diagram - Cast

45Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Page 41 - Parts List - Components

5SpecificationsWARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxid

Page 42

6Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before OperatingWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCT

Page 43 - Parts Diagram - Components

72. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several

Page 44 - Warranty

8Electronicignition moduleMaintenance And ServiceROUTINE MAINTENANCE:At least once a year, run through the following procedures to ensure the system i

Page 45 - Installation Data Sheet

Figure 7: Handles for Removing Door.Figure 8: Removing of Door.Maintenance And ServiceREPLACING THE GLASS:The glass in the replace is a high temperat

Comments to this Manuals

No comments