
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R I E S
Initial InstallationQUALIFIED INSTALLERS ONLYINTRODUCTION: This section of the owner’s manual is for the use of qualied technicians only. Fireplace
Initial InstallationQUALIFIED INSTALLERS ONLYCORNER INSTALLATION: The dimensions for installing a replace in the corner of a room are given below in
Initial InstallationQUALIFIED INSTALLERS ONLYProtector pad,cement board andfinishing material.Do not tilehigher thanthis ledgeCement boardProtector Pa
Initial InstallationQUALIFIED INSTALLERS ONLYMANTLE CLEARANCES: It is not necessary to install a mantle, but if one is desired it is important to foll
Letter Canadian Installation 1US Installation2DescriptionA 12in (30cm) Clearance above grade, verandah, porch, deck, or balcony.B 12in (30cm) 9in (
Initial InstallationQUALIFIED INSTALLERS ONLYVENTING: This replace has been tested and certied for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” P
Initial InstallationQUALIFIED INSTALLERS ONLYFigure 18. Possible Vent Congurations16Vent Restrictor Positions5 4 3 2 1Vent RestrictorFigure 19. Possi
Initial InstallationQUALIFIED INSTALLERS ONLYHORIZONTAL TERMINATION:Step 1. Set the replace in the desired location. Check to determine if wall stud
Initial InstallationQUALIFIED INSTALLERS ONLYVERTICAL TERMINATION: attic rafters. See end of this section. Do not pack air spaces with insu
Step 6. Once the pipe sections have been joined and run up through the roof, slip a pipe support strap over the exposed sections. Bend the support str
FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIROGAS” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All ENVIRO gas-red applianc
ROOF PITCH MIN DISTANCEft mat to 7/12 1 0.3>7/12 to 8/12 1.5 0.46>8/12 to 9/12 2 0.61>9/12 to 10/12 2.5 0.76>10/12 to 11/12 3.25 0.99>
21Initial InstallationQUALIFIED INSTALLERS ONLYELECTRICAL SYSTEM: The replace must be electrically connected and grounded in accordance with local co
GAS LINE CONNECTION: Warning: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.G
23Secondary InstallationGLASS REMOVAL: In order to install the log set, and for regular cleaning, the glass door will need to be removed. With the fa
Secondary InstallationFigure 29: Shows the back log plus the two small log twigs. Put the large back log in rst, making sure the locator pins line up
Figure 33: Final Log Set Arrangement with Embers.25Secondary InstallationFigure 34: DV42DX Burning.Figure 32: Fourth Stage Log Set Installation.Fig
26Secondary InstallationVENTURI ADJUSTMENT: The venturi adjustment lever is centered above the control panel.The venturi allows the amount of air comi
Trouble ShootingProblem Possible Cause SolutionSpark will not light the pilot after repeatedly pressing the spark ignitorDefective piezo ignitor
Parts ListPart NumberDescription50-633 Door, Glass & Gasket50-634 Dual bulb door gasket (10ft)50-635 Door Handle Set50-632 Door Latch Mechanism50-
29Parts Diagram
Table of Contents3Safety Precautions...2Table of Conte
IndexAAdjustingAir Diverter 7Fan Speed. See Blower SpeedFlame Height 7Venturi 26BBlower Speed 7BTU Input/Output 22CCap. See Vent CapClearances 1
31WarrantySherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This Limited Lifetime Warranty covers the appliance for a
32Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________
Codes And ApprovalsDIRECT VENT: This type is identied by the prex DV. This appliance draws all of its air for combustion from outside the dwel
INSTALLATION OPTIONS: • Parallel to a wall or placed in a corner • With a oor hearth or raised up the wall • Ducting to other rooms
Operating InstructionsBEFORE LIGHTING: This appliance is equipped with a pilot, which must be lit by following these instructions exactly:A) BEFORE
Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before OperatingWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTI
Maintenance And ServiceROUTINE MAINTENANCE:At least once a year, run through the following procedures to ensure the system is clean and working proper
Maintenance And ServiceFUEL CONVERSION:Warning: A qualied service technician, in accordance with the manufacturer’s instructions as well as all appl
Comments to this Manuals