SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
B Y : S H E R W O O D I N D U S T R I E S L T D
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
50-1630
Cara
This appliance may be installed in an after-
market permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certied kit is used.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open ame.
• Do not try to light any appliance.
• Do not touch any electrical switch or use
any phone in your building.
• Immediately call your gas supplier from
a neighbours phone. Follow the gas
suppliers instructions.
• If you cannot reach your gas supplier, call
the re department.
WARNING: If the information in this
manual is not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of
life. Installation and service must be
performed by a qualied installer,
service agency or the gas supplier.
FOR YOUR SAFETY: Do not store or use gasoline
or other ammable vapours and liquids in the
vicinity of this or any other appliance.
Massachusetts installations (Warning): This product must be installed by a licensed plumber or
gas tter when installed within the Commonwealth of Massachusetts. Other Massachusetts code
requirements: Flexible connector must not be longer than 36in., a shut off valve must be installed;
only direct vent sealed combustion products are approved for bedrooms/bathrooms. A carbon
monoxide detector is required in all rooms containing gas red direct vent appliances. The replace
damper must be removed or welded in the open position prior to installation of a replace insert.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
OWNERS MANUAL
Page view 0
1 2 3 4 5 6 ... 41 42

Summary of Contents

Page 1 - OWNER’S MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R I E S

Page 2 - Safety Precautions

IMPORTANT: Ensure the unit is off and at room temperature. To remove the burner:1. Remove the glass door as shown in the MAINTENANCE AND SERV

Page 3 - Table of Contents

11Maintenance And ServiceFUEL CONVERSION:TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLYPlease read and understand these instructions before instal

Page 4 - Codes And Approvals

12Figure 14: Removing valve cap.Maintenance And Servicescrew must be not visible.Figure 16: Flip valve screw.Red o-ringis not visibleRed o-ringis visi

Page 5 - Specifications

Initial InstallationQUALIFIED INSTALLERS ONLYWARNING: Operation of this heater when not connected to a properly installed and maintained venting syste

Page 6 - Operating Instructions

Initial InstallationQUALIFIED INSTALLERS ONLYPLANNING YOUR INSTALLATION:VerticalTerminationStorm CollarFlashingRound SupportBox/Wall ThimbleCeiling Fi

Page 7

When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to no

Page 8

16Table 6: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS).Direct Vent GS Direct-Temp Secure Vent Ameri Vent Direct Descri

Page 9

171 In accordance with the current CSA B149, Natural Gas and Propane Installation Code.2 In accordance with the current ANSI Z223.1 NFPA 54, National

Page 10 - Maintenance And Service

Initial InstallationQUALIFIED INSTALLERS ONLYVENT CONFIGURATIONS AND RESTRICTOR SETTINGS:Figure 24 and 25 shows the range of possible vent conguratio

Page 11

19Initial InstallationQUALIFIED INSTALLERS ONLYRESTRICTOR INSTALLATION:The ENVIRO CARA has been designed for use with an add-in restrictor. The restri

Page 12

2FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All ENVIRO gas-red appliances must b

Page 13 - Initial Installation

Initial InstallationQUALIFIED INSTALLERS ONLYHORIZONTAL INSTALLATION:1. Set the appliance in the desired location. Check to determine if wall studs or

Page 14

21Initial InstallationQUALIFIED INSTALLERS ONLYWood screws (x4)Cut vinyl sidingaway to fit standoffBolt (x4)requiredNut (x4)requiredWoodscrew (x4)Figu

Page 15

3. To install the Round Support Box/Wall Thimble in a at ceiling, cut a 10” square hole in the ceiling, centered in the hole drilled in Step 2. Fram

Page 16

23the support straps that extend out beyond the edge of the ashing.7. Slip the ashing over the pipe section protruding through the roof. Secure the

Page 17

plumber’s tapeconnected towall strapWall strap45° elbows (x2)NailsCeiling firestopCeilingSecond floorUse clearances to asdefined by appliance andvent

Page 18

25Figure 39: Cathedral Ceiling Support Box Installation.Initial InstallationQUALIFIED INSTALLERS ONLYFigure 40: Corner installation rear vented with s

Page 19

Vent PipeInside Finished CollarDry WallWall ThimbleExterior WallSidingMinimum Vent Terminal 36”(914mm) High Snorkel Kit.Figure 43: Installation for Re

Page 20

Vent CapInside Finished CollarCeiling SupportInsulation GuardFlue PipeRoof TrussRoof Flashing27Initial InstallationQUALIFIED INSTALLERS ONLYINSTALLATI

Page 21

Initial InstallationQUALIFIED INSTALLERS ONLYGAS LINE CONNECTION AND TESTING:WARNING: Only persons licensed to work with gas piping may make the neces

Page 22

Initial InstallationQUALIFIED INSTALLERS ONLYELECTRICAL REQUIREMENTS FOR GAS VALVE AND OPTIONAL BLOWER:The ENVIRO CARA will operate without electrical

Page 23

Table of Contents3Safety Precautions...2Table of Con

Page 24

Figure 49: Optional Blower (Fan) Installation.1. Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage is noti

Page 25

Figure 52: Log Placement of Right Log.31The placement of the logs is not arbitrary. If they are positioned incorrectly, the ames can be “pinched” and

Page 26

Secondary Installation32Secondary InstallationFigure 55: Log Placement Complete.Figure 53: Log Placement of Left Log.Left LogCenter LogFigure 54: Log

Page 27

Figure 56: Cara with a Good Flame.CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED.Important note: When the unit is turned on for the

Page 28

Secondary InstallationINSTALLATION OF CERAMIC FIREBOX LINER (OPTIONAL):Figure 57: Steel Firebox Liners Installation.Figure 58: Firebox Liners Installa

Page 29 - QUALIFIED INSTALLERS ONLY

35Trouble ShootingProblem Possible Cause SolutionThe main burner does not ignite when called for.The gas valve may not be on. • Check that the gas

Page 30

Parts List36Reference NumberPart Description Part Number1 120°F (49°C) Ceramic Fan Temperature Sensor EC-001Thermopile EC-0122 S.I.T. Piezo Igniter EC

Page 31 - Secondary Installation

37Parts ListReference NumberPart Description Part Number10 Cara Firebox Bafe 50-159511 Cara Main Orice NG (PO512-37) 50-159611 Cara Main Orice LPG

Page 32

Parts Diagram3813245678910131415161718192123242526201222112728

Page 33

39WarrantySherwood Industries Ltd. is the manufacturer of the VistaFlame line of heating products. At Sherwood Industries, our commitment to the highe

Page 34

4DIRECT VENT ONLY: This type is identied by the sux DV. This appliance draws all of its air for combustion from outside the dwelling, through a spec

Page 35 - Trouble Shooting

4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs of negle

Page 36 - Parts List

4120. Sherwood Industries Ltd. is free of liability for any damages caused by the replace or stove, as well as inconvenience expenses and materials.

Page 37

42Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Page 38 - Parts Diagram

5SpecificationsWARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxid

Page 39 - Warranty

6Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before Operating.WARNING: IF YOU DO NOT FOLLOW THESE INSTRUC

Page 40

7AIR SHUTTER:Air Shutter Adjustment NutFigure 5: Air Shutter Adjustment.The air shutter is controlled by sliding the air shutter adjustment s

Page 41

Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before Operating8The ideal ame will be blue at the base and

Page 42 - Installation Data Sheet

9Maintenance And ServiceROUTINE MAINTENANCE:At least once a year, run through the following procedures to ensure the system is clean and working prope