Enviro Kodiak 1700 Fireplace Freestanding User Manual

Browse online or download User Manual for Tools Enviro Kodiak 1700 Fireplace Freestanding. Enviro Kodiak 1700 Fireplace Freestanding User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 50
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNERS MANUAL
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Kodiak
Wood Stove
Models: 1200 & 1700 Insert and 1200 & 1700 Fireplace Freestanding
Tested &
Listed By
Beaverton
Oregon USA
OMNI-Test Laboratories, Inc,
C
O-
T L
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD
BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT
IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
Contact your local building or re ofcials, or the authority having jurisdiction
about restrictions and installation inspection requirements in your area.
This heater meets the U. S. Environmental Protection Agencies
emission limits for wood heaters sold after July 1st, 1990.
Under specic conditions this heater has been shown to deliver
heat at rates ranging from 11,479 to 34,196 BTU per hour for
the 1200 and from 9,425 to 31,780 BTU per hour for the 1700.
50-1040
Page view 0
1 2 3 4 5 6 ... 49 50

Summary of Contents

Page 1 - OWNER’S MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R I E S

Page 2 - Table of Contents

Operating InstructionsHOW IT WORKS:1/2" Ceramic baffle;reflects heat downto burn up smoke.Secondary air tubes;creates a secondaryburn on the part

Page 3 - Safety Precautions

11Specifications1200 SPECIFICATIONS:Model 1200 Freestanding 1200 InsertFlat Top Step TopWidth x Depth 25” x 22 7/16” (635 mm x 570 mm)27” x 21” (70

Page 4

Specifications1700 SPECIFICATIONS:Model 1700 Freestanding 1700 InsertFlat Top Step TopWidth x Depth 25” x 26 15/16” (635 mm x 684 mm)27” x 26” (705

Page 5

13SpecificationsCLEARANCES TO COMBUSTIBLES - 1200 INSERT:A Minimum clearance to an unshielded side wall10” (254 mm)B Minimum clearance to an unshielde

Page 6

SpecificationsCLEARANCES TO COMBUSTIBLES - 1200 FREESTANDING:MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*Single Wall Pipe Double Wall

Page 7

15SpecificationsCLEARANCES TO COMBUSTIBLES - 1700 FREESTANDING:MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*Single Wall Pipe Double Wa

Page 8

SpecificationsDIMENSIONS - 1200 INSERT:3/16"(5mm)183/8"(467mm)Regular Surround2715/16" (709mm)OversizedSurround333/16"(709mm)191/8

Page 9

17SpecificationsDIMENSIONS - 1200 INSERT:337/8" (860mm)461/8" (1171mm)273/4" (705mm)3/16"(5mm)183/8"(467mm)Regular Surround27

Page 10 - Operating Instructions

SpecificationsDIMENSIONS - 1200 FREESTANDING:25"(635mm)61/16"(153mm)915/16"(252mm)281/4"(718mm)2915/16"(760mm)301/4"(769

Page 11 - Specifications

19SpecificationsDIMENSIONS - 1700 FREESTANDING:2615/16"(684mm)915/16"(252mm)157/8"(403mm)25"(635mm)193/8"(492mm)61/16"(1

Page 12

Table of Contents2Safety Precautions...3Operating Instructi

Page 13

SpecificationsFREESTANDING SIDE DIMENSIONS FOR FAN KIT:    

Page 14

21InstallationPlease read and understand these instructions before installing pedestal or ash pan and leg option. Failure to follow thes

Page 15

• Place the unit on the pallet on its back.• Attach pedestal spacer to bottom of the unit, using the supplied screws.• Attach the air channel box

Page 16

23InstallationOUTSIDE AIR KIT:It is mandatory to use outside air for installations in mobile homes.A 4” (10.2 cm) fresh air adaptor kit is av

Page 17

InstallationCHIMNEY INSTALLATION THROUGH WALL:Here are four (4) methods of combustible wall chimney connector pass-throughs. Information was provided

Page 18

25InstallationINSTALLATION OF A LISTED, FACTORY BUILT CHIMNEY - FREESTANDING:This is a generic set of instructions; always follow the chimney manufact

Page 19

InstallationHearthpadFloorPedestalWoodstoveOptionalfanOutside air connectionthrough wall or floorChimneyconnectorCeilingInsulated chimneyRoof flashing

Page 20

27InstallationMASONRY CHIMNEY INSTALLATION - FREESTANDING:DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.A non-combustible oo

Page 21 - Installation

Figure 29: Freestanding Installation into existing replace.Unless you are experienced, we recommend installation by your dealer or a professional ins

Page 22

29At least3 feet (914 mm)HearthpadFloorPedestalWoodstoveOptionalfanOutside air connectionthrough wall or floorDouble wall pipeCeiling supportCeilingSp

Page 23

3Safety PrecautionsFOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” WOOD STOVE, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:● Please read this

Page 24

InstallationMASONRY FIREPLACE INSTALLATION - INSERT:Unless you are experienced, we recommend installation by your dealer or a professional installer.I

Page 25

The ue collar is removable for installations into replaces with low openings. a) Remove the rst two (2) front secondary air tube

Page 26

32InstallationFigure 35: Attaching removable ue.Figure 36: Leveling leg.SURROUND PANEL SEALED INSTALLATION FOR USA ONLY - INSERT:Before starting th

Page 27

33InstallationINSTALLATION USING A BLOCK-OFF PLATE FOR USA ONLY - INSERT:If this unit is to be installed into a masonry replace or a zero-clearance 

Page 28

34Installation5. Mount the block-off plate using masonry screws in a masonry replace and sheet metal screws on a zero-clearance repl

Page 29

InstallationMODEL 1200 BRICK PLACEMENT & TUBE LOCATIONS:COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.When replacing

Page 30

InstallationMODEL 1700 BRICK PLACEMENT & TUBE LOCATIONS:COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.When replacing

Page 31

37InstallationDOOR INSTALLATION:Please inspect all components for damage. If damage has occurred, please contact the courier company, dealer, or distr

Page 32

CERAMIC BAFFLE INSTALLATION:1. Remove the front secondary air tube by placing a screwdriver (any style except at head) into one of Left CeramicBaffle

Page 33

39The fan kit is pre-installed into the left shroud that comes with your unit. If a decorative set of shroud plates is purchased, the fan as

Page 34

Operating InstructionsFIRST STARTWhen rst installed, the chimney, rebricks and steel are cold and it usually takes several hours on a fairly high bu

Page 35

Figure 52: Changing decorative plate.InstallationREMOVAL OF THE SHROUDS - INSERT:ABB1. If the surround panel is installed, remove it by lifting the p

Page 36

41InstallationINSTALLATION OF THE SURROUND PANEL - INSERT:Figure 55: Screw to hold the trim against the sur-round.Figure 53: Corner brackets for trim.

Page 37

Parts ListReferance NumberDescription Part Number1 120°F (49°C) Ceramic Fan Temperature Sensor EC-0012 Domestic power cord - 115V EC-042Convection Blo

Page 38

43Parts ListReferance NumberDescription Part Number26 Door Handle Assembly (Rod, Cast Latch, Brass Spring) 50-112127 Wood Door Glass Retainer Kit (Wit

Page 39

Parts Diagram - Freestanding3130343529283332151719184625444277926142161721202322244345816Kodiak - Freestanding ComponentsOctober 200444

Page 40 - Figure 52: Changing

45Parts Diagram - Pedestals & Legs111310124139405383637Kodiak - Pedestal and Leg Kit ComponentsMay 2006

Page 41 - Figure 55: Screw to hold

Parts Diagram - Fireplace Insert4915535447850485152544223Kodiak - Fireplace Insert ComponentsOctober 2004Common parts are shown inParts Diagram - Free

Page 42 - Parts List

47WarrantySherwood Industries Ltd. Limited Lifetime WarrantySherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sh

Page 43

Warranty6. If the problem is not covered by the Limited Warranty, the customer will be responsible for all repair costs, as well as all storage, shi

Page 44 - Parts Diagram - Freestanding

49d) Salt air in coastal areas or high-humidity can be corrosive to the nish; these environments can cause rusting. Damage caused by

Page 45 - May 2006

REPLACING THE GLASS:Never strike or slam the door, hit the glass or let burning wood rest against it. If the glass cracks when the re is burning, do

Page 46 - Common parts are shown in

50Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Page 47 - Warranty

6Operating InstructionsMAINTENANCE:At the end of each heating season clean the chimney and the smoke pipe. If soot has accumulated above the top bafe

Page 48

7Operating Instructionsc) DO NOT OVERFIRE. If the heater or chimney connector glows, you are overring.d) CAUTION: DO NOT PLACE FUEL WITHIN SPACE HEAT

Page 49

8Operating Instructionslength for the logs used in the 1200 would be about 16“ (381 mm) but it can burn pieces up to 18” long. Ideal length for the lo

Page 50 - Installation Data Sheet

9Operating Instructionsa) Air supply – Inside the home, normal household appliances such as clothes dryers and forced-air furnaces compe

Comments to this Manuals